Summary
Segun Osidele is an API 510 Inspector and QA/QC professional with many years of experience in the energy industry, specializing in mechanical integrity across oil field, refinery, chemical, petrochemical, gas plant, and FLNG environments. He has performed internal and external inspections of pressure vessels, exchangers, drums, heaters, towers, piping systems, welds, flanges, and gasket seating surfaces. His experience includes QA/QC inspection of piping fabrications, repairs, and pressure-vessel alterations, as well as witnessing load and pressure testing on exchangers and piping systems. Segun has supported major clients and facilities including ExxonMobil, Chevron Phillips, Valero, P66, Enterprise, Kinder Morgan, and Dow. He also prepares inspection reports, reviews turnover packages, and conducts Job Safety Analysis.
summary may omit high-priority source evidence: API 510 Inspector with API 510 credential #49782, expiring 11/30/28.
summary repeats certification detail from qualifications (API 510) — review
Education
- Computer Science at Kwara State Polytech. Nigeria
- High School Certificate. Nigeria
Qualifications and Training
- NDT training at The Ocean Corporation, Houston, TX (2006), trained and tested by ANST-TC-1A Specification level I and II, covering radiography inspection, ultrasonic inspection, magnetic particle, liquid dye penetrant, and visual inspection
- API 510: #49782 exp. 11/30/28
- TWIC Card exp. 04/30/28
- Valid TX Driver L. exp. 04/16/2032
Work Experience
Oct 2021 – Oct 2026
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections on pressure vessels, exchangers, and drums in compliance with API 510 code standards.
- Conducted visual inspections of welds, piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
⚠ Review: dates overlap with Foley Specialty Services; dates overlap with Loenbro Inspection; dates overlap with Southern Services Inc; dates overlap with Team Industrial Services; dates overlap with Sentinel Integrity Inspection; dates overlap with Engineering Inspection Services; dates overlap with Spartan Company; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; dates overlap with Tear1 Integrity; dates overlap with Weld Spec Inspection; employer replaced on AI judgment alone — verify agency status
May 2024 – Nov 2025
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections of pressure vessels, exchangers, drums and heaters, adhering to the API 510 code standard.
- Verified that all piping fabrications and equipment adhered to relevant industry standards.
- Witnessed load and pressure testing on piping systems to ensure operational integrity.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Loenbro Inspection; dates overlap with Southern Services Inc; dates overlap with Team Industrial Services; dates overlap with Sentinel Integrity Inspection; dates overlap with Engineering Inspection Services; employer replaced on AI judgment alone — verify agency status
Jun 2025 – Jun 2025
TPI AGENCY
API 510 Inspector
- Performed internal and external inspection and maintenance on LPG pressure vessels in compliance with API 510 code standards.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Foley Specialty Services
Feb 2025 – May 2025
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections of pressure vessels, exchangers, drums and heaters, adhering to the API 510 code standard.
- Conducted visual inspections of piping systems, welds and flange gasket seating surfaces to ensure integrity and compliance.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Foley Specialty Services; employer replaced on AI judgment alone — verify agency status
Jan 2025 – Feb 2025
TPI AGENCY
API 510 Inspector
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Foley Specialty Services; employer replaced on AI judgment alone — verify agency status
Sep 2016 – Oct 2024
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections of pressure vessels, exchangers, drums, heaters, and towers, adhering to the API 510 code standard.
- Performed visual inspections of piping systems, flanges, welds and gasket seating surfaces to ensure proper sealing and integrity.
- Performed QA/QC field inspector to ensure all piping fabrications, repairs, and alterations to pressure vessels conformed to relevant codes and standards.
- Wrote clear and precise inspection reports and recommendations.
- Reviewed turnover packages provided by contractors and ensured they met customer requirements.
- Conducted JSA to identify any potential hazards before starting any work activity on the field.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Foley Specialty Services; dates overlap with Engineering Inspection Services; dates overlap with Spartan Company; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; dates overlap with Tear1 Integrity; dates overlap with Weld Spec Inspection; dates overlap with Precision NDT; dates overlap with Mistras Inspection; dates overlap with ABS Consulting; dates overlap with Techcorr Inspection Services; dates overlap with Amerapex Corporation
Aug 2024 – Sep 2024
TPI AGENCY
API 510 Inspector
- Performed external visual inspections of various pipe rack structures across refinery sites for a proposed Global Project.
- Assessed structural integrity and compliance with project specifications to ensure safety and operational standards.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Foley Specialty Services; dates overlap with Sentinel Integrity Inspection
Mar 2023 – Sep 2023
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections of pressure vessels, exchangers, drums and heaters, adhering to the API 510 code standard.
- Conducted visual inspections of piping systems, welds and flange gasket seating surfaces to ensure integrity and compliance.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Sentinel Integrity Inspection; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; employer replaced on AI judgment alone — verify agency status
Mar 2014 – Aug 2023
TPI AGENCY
API 510 Inspector
- Performed visual inspections of piping systems and flange gasket seating surfaces.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Sentinel Integrity Inspection; dates overlap with Spartan Company; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; dates overlap with Tear1 Integrity; dates overlap with Weld Spec Inspection; dates overlap with Precision NDT; dates overlap with Mistras Inspection; dates overlap with ABS Consulting; dates overlap with Techcorr Inspection Services; dates overlap with Amerapex Corporation; dates overlap with American Inspection Services; dates overlap with CTS Inspection; dates overlap with Turner-Ind. Inspection Services; dates overlap with Intertek; dates overlap with CAN USA Inspection; employer replaced on AI judgment alone — verify agency status
Jan 2017 – Jun 2023
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections of pressure vessels, exchangers, drums, heaters, and towers, adhering to the API 510 code standard.
- Witnessed all load and pressure testing on exchangers to ensure compliance with safety and operational standards.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Sentinel Integrity Inspection; dates overlap with Spartan Company; dates overlap with IRIS NDT; dates overlap with Versa Integrity Group; dates overlap with Tear1 Integrity; dates overlap with Weld Spec Inspection; dates overlap with Precision NDT; dates overlap with Mistras Inspection; dates overlap with ABS Consulting; dates overlap with Techcorr Inspection Services; dates overlap with Amerapex Corporation
Mar 2019 – Aug 2022
TPI AGENCY
API 510 Inspector
- Conducted internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in accordance with API 510 code standards.
- Performed visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
- Performed QA field inspector, ensuring all piping fabrications, repairs, and alterations to pressure vessels met specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with safety and operational standards.
- Performed QA/QC inspections on vessels, piping, flanges, and control valves to ensure compliance with specified codes and standards.
- Verified that all piping fabrications and equipment met industry requirements.
- Collaborated with CB&I Commissioning Group on pressure vessels, piping systems, and compressor generators during project commissioning.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Sentinel Integrity Inspection; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Tear1 Integrity; dates overlap with Weld Spec Inspection; dates overlap with Precision NDT; dates overlap with Mistras Inspection; dates overlap with ABS Consulting; dates overlap with Techcorr Inspection Services; dates overlap with Amerapex Corporation; employer replaced on AI judgment alone — verify agency status
Jul 2022 – Jul 2022
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Sentinel Integrity Inspection; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; employer replaced on AI judgment alone — verify agency status
Jan 2020 – May 2022
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in accordance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure proper sealing and integrity.
- Served as a QA field inspector, ensuring all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to ensure compliance with operational and safety standards.
⚠ Review: dates overlap with Pro-Surve Technical Services; dates overlap with Sentinel Integrity Inspection; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; dates overlap with Precision NDT; dates overlap with Mistras Inspection; dates overlap with ABS Consulting; dates overlap with Techcorr Inspection Services
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
⚠ Review: start date missing or unclear; end date missing or unclear
Jul 2021 – Jul 2021
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections and maintenance on pressure vessels in compliance with API 510 code standards.
⚠ Review: dates overlap with Sentinel Integrity Inspection; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; dates overlap with Weld Spec Inspection; employer replaced on AI judgment alone — verify agency status
Jan 2021 – Apr 2021
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
- Reviewed turnover packages from contractors and for the customer, ensuring all documentation was accurate and met project requirements.
⚠ Review: dates overlap with Sentinel Integrity Inspection; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; dates overlap with Weld Spec Inspection
Dec 2019 – Nov 2020
TPI AGENCY
API 510 Inspector
- Performed internal and external inspection and maintenance on pressure vessels in compliance with API 510 code standards.
⚠ Review: dates overlap with Sentinel Integrity Inspection; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; dates overlap with Weld Spec Inspection; dates overlap with Techcorr Inspection Services
Apr 2020 – Apr 2020
TPI AGENCY
API 510
- Ensured all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes and standards.
- Witnessed all load and pressure testing on exchangers and piping systems to ensure compliance with operational and safety standards.
- Prepared and reviewed turnover packages for both the customer and contractors, ensuring all documentation met project requirements.
⚠ Review: dates overlap with Sentinel Integrity Inspection; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; dates overlap with Weld Spec Inspection; dates overlap with ABS Consulting
Jul 2016 – Jul 2019
TPI AGENCY
API 510
- Conducted initial walk-down on piping and equipment, reviewing the vessels' prior inspection history, repairs, and current inspection plans.
- Performed inspections on the FCCU structure, including the regenerator, cyclones, and reactors, ensuring compliance with API 510 and API 570 code standards.
- Wrote clear and precise inspection reports and recommendations in accordance with client policies and procedures.
- Conducted external piping inspections and internal inspections of pressure vessels.
- Performed Job Safety Analysis (JSA) to identify potential hazards before commencing field work activities.
- Ensured all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes and standards.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
- Prepared and reviewed turnover packages for both the customer and contractors, ensuring all documentation met project requirements.
⚠ Review: dates overlap with Sentinel Integrity Inspection; dates overlap with IRIS NDT; dates overlap with Acuren Inspection; dates overlap with Versa Integrity Group; employer replaced on AI judgment alone — verify agency status
Feb 2016 – Mar 2016
TPI AGENCY
API 510
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in accordance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
- Acted as a QA field inspector to ensure that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to ensure compliance with operational and safety standards.
- Prepared and reviewed turnover packages for the customer and contractors, ensuring all documentation met project requirements.
⚠ Review: dates overlap with IRIS NDT
Oct 2015 – Nov 2015
TPI AGENCY
API 510
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
⚠ Review: dates overlap with IRIS NDT
Apr 2015 – May 2015
TPI AGENCY
API 510
- Performed internal and external inspections on pressure vessels, exchangers, drums, and towers in compliance with API 510 code standards.
- Witnessed all load and pressure testing on exchangers to ensure compliance with safety and operational standards.
⚠ Review: dates overlap with IRIS NDT
Jul 2014 – Mar 2015
TPI AGENCY
API 510
- Performed internal and external inspections on pressure vessels, exchangers, drums, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems to ensure integrity and compliance.
- Provided QA/QC support in the fabrication shop and as a field inspector to ensure all piping fabrications, repairs, and alterations to pressure vessels met specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
- Reviewed turnover packages from contractors to ensure all documentation met customer specifications.
⚠ Review: dates overlap with IRIS NDT
Apr 2014 – May 2014
TPI AGENCY
API 510 Inspector
- Performed internal and external inspections on pressure vessels, exchangers, drums, and towers in compliance with API 510 code standards.
⚠ Review: dates overlap with IRIS NDT
Projects
SEP 2026 – OCT 2026
Client: HF Sinclair Refinery, El-dorado. KS.
HF Sinclair Refinery, El-dorado. KS. (Sept to Oct 2026 TA)
- Performed internal and external inspections on pressure vessels, exchangers, and drums in compliance with API 510 code standards.
- Conducted visual inspections of welds, piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
OCT 2021 – OCT 2021
Client: Celanese Chemical Plant, Bay City, TX.
Celanese Chemical Plant, Bay City, TX. (Oct 2021, TA)
- Performed internal and external inspections on pressure vessels, exchangers, and drums in compliance with API 510 code standards.
- Conducted visual inspections of welds, piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
OCT 2025 – NOV 2025
Client: OXY Vinyls chemical Plant, Deer park, TX.
OXY Vinyls chemical Plant, Deer park, TX. (Area 100, 150, 200 and HCN units TA. Oct-Nov. 2025)
- Performed internal and external inspections of pressure vessels, exchangers, drums and heaters, adhering to the API 510 code standard.
- Verified that all piping fabrications and equipment adhered to relevant industry standards.
- Witnessed load and pressure testing on piping systems to ensure operational integrity.
SEP 2025 – SEP 2025
Client: Nucor Steel, Donaldsonville, LA
Nucor Steel, Donaldsonville, LA (Plant wide TA Sept. 2025)
- Performed internal and external inspections of pressure vessels, exchangers, drums and heaters, adhering to the API 510 code standard.
- Verified that all piping fabrications and equipment adhered to relevant industry standards.
- Witnessed load and pressure testing on piping systems to ensure operational integrity.
MAY 2024 – MAY 2024
Client: OXY chemical Plant, Geismar, LA.
OXY chemical Plant, Geismar, LA. (TA. May 2024)
- Performed internal and external inspections of pressure vessels, exchangers, drums and heaters, adhering to the API 510 code standard.
- Verified that all piping fabrications and equipment adhered to relevant industry standards.
- Witnessed load and pressure testing on piping systems to ensure operational integrity.
JUN 2025 – JUN 2025
Client: Petro Hunt Gas Plant. Killdeer, North Dakota
Petro Hunt Gas Plant. Killdeer, North Dakota June 2025
Product: LPG pressure vessels
- Performed internal and external inspection and maintenance on LPG pressure vessels in compliance with API 510 code standards.
FEB 2025 – MAY 2025
Client: Ascend Performance Materials Plant. Alvin, Texas.
Ascend Performance Materials Plant. Alvin, Texas. (APM-AN7 & LAB units TA Feb, 2025 - May, 2025)
- Performed internal and external inspections of pressure vessels, exchangers, drums and heaters, adhering to the API 510 code standard.
- Conducted visual inspections of piping systems, welds and flange gasket seating surfaces to ensure integrity and compliance.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
FEB 2025 – FEB 2025
Client: Enterprise Plant, Mount Belview, Texas.
Enterprise Plant, Mount Belview, Texas. Feb 2025. A week CUI project.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
JAN 2025 – JAN 2025
Client: MEGlobal Canada ULC Plant, Freeport, Texas; AAM & Fab shop at Texas City, TX
MEGlobal Canada ULC Plant, Freeport, Texas Plant wide /AAM & Fab shop at Texas City, TX: TA Jan 2025
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
OCT 2024 – OCT 2024
Client: Indorama Petrochem. Port Arthur, TX
Indorama Petrochem. Port Arthur, TX T/A Oct 2024
- Performed internal and external inspections of pressure vessels, exchangers, drums, heaters, and towers, adhering to the API 510 code standard.
- Performed visual inspections of piping systems, flanges, welds and gasket seating surfaces to ensure proper sealing and integrity.
- Performed QA/QC field inspector to ensure all piping fabrications, repairs, and alterations to pressure vessels conformed to relevant codes and standards.
- Wrote clear and precise inspection reports and recommendations.
- Reviewed turnover packages provided by contractors and ensured they met customer requirements.
- Conducted JSA to identify any potential hazards before starting any work activity on the field.
DEC 2023 – MAY 2024
Client: P66 Refinery Plant, Rodeo, California.
P66 Refinery Plant, Rodeo, California. Plant Wide Renewable TA Dec 2023 – May 2024
- Performed internal and external inspections of pressure vessels, exchangers, drums, heaters, and towers, adhering to the API 510 code standard.
- Performed visual inspections of piping systems, flanges, welds and gasket seating surfaces to ensure proper sealing and integrity.
- Performed QA/QC field inspector to ensure all piping fabrications, repairs, and alterations to pressure vessels conformed to relevant codes and standards.
- Wrote clear and precise inspection reports and recommendations.
- Reviewed turnover packages provided by contractors and ensured they met customer requirements.
- Conducted JSA to identify any potential hazards before starting any work activity on the field.
SEP 2023 – NOV 2023
Client: Monroe Energy, Plant. Philadelphia.
Monroe Energy, Plant. Philadelphia. Plant wide TA Sept 2023 – Nov. 2023
- Performed internal and external inspections of pressure vessels, exchangers, drums, heaters, and towers, adhering to the API 510 code standard.
- Performed visual inspections of piping systems, flanges, welds and gasket seating surfaces to ensure proper sealing and integrity.
- Performed QA/QC field inspector to ensure all piping fabrications, repairs, and alterations to pressure vessels conformed to relevant codes and standards.
- Wrote clear and precise inspection reports and recommendations.
- Reviewed turnover packages provided by contractors and ensured they met customer requirements.
- Conducted JSA to identify any potential hazards before starting any work activity on the field.
SEP 2016 – OCT 2016
Client: PBF Energy Plant Paulsboro, NJ.
PBF Energy Plant Paulsboro, NJ. T/A Sept 2016 –Oct. 2016
- Performed internal and external inspections of pressure vessels, exchangers, drums, heaters, and towers, adhering to the API 510 code standard.
- Performed visual inspections of piping systems, flanges, welds and gasket seating surfaces to ensure proper sealing and integrity.
- Performed QA/QC field inspector to ensure all piping fabrications, repairs, and alterations to pressure vessels conformed to relevant codes and standards.
- Wrote clear and precise inspection reports and recommendations.
- Reviewed turnover packages provided by contractors and ensured they met customer requirements.
- Conducted JSA to identify any potential hazards before starting any work activity on the field.
AUG 2024 – SEP 2024
Client: ExxonMobil Beaumont and Baytown, TX
ExxonMobil Beaumont and Baytown, TX. Aug to Sept. 2024
Product: Pipe rack structures
- Performed external visual inspections of various pipe rack structures across refinery sites for a proposed Global Project.
- Assessed structural integrity and compliance with project specifications to ensure safety and operational standards.
AUG 2023 – SEP 2023
Client: CFI Plant, Donaldsonville, LA
CFI Plant, Donaldsonville, LA (Amonia 1 unit TA Aug, 2023-Sept, 2023)
- Performed internal and external inspections of pressure vessels, exchangers, drums and heaters, adhering to the API 510 code standard.
- Conducted visual inspections of piping systems, welds and flange gasket seating surfaces to ensure integrity and compliance.
MAR 2023 – MAR 2023
Client: OXY chemical Plant, Geismar, LA.
OXY chemical Plant, Geismar, LA. (TA. March, 2023)
- Performed internal and external inspections of pressure vessels, exchangers, drums and heaters, adhering to the API 510 code standard.
- Conducted visual inspections of piping systems, welds and flange gasket seating surfaces to ensure integrity and compliance.
JUL 2023 – AUG 2023
Client: Sinclair Refinery, Cassper, WY
Sinclair Refinery, Cassper, WY Plant wide TA July 2023 – Aug. 2023
- Performed visual inspections of piping systems and flange gasket seating surfaces.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
APR 2023 – MAY 2023
Client: Sinclair Refinery, Rawlings WY
Sinclair Refinery, Rawlings WY Plant wide TA April 2023 – May 2023
- Performed visual inspections of piping systems and flange gasket seating surfaces.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
JAN 2023 – FEB 2023
Client: Delek refining Plant, Tyler, Texas; Ohmstede shop at Laporte TX
Delek refining Plant, Tyler, Texas Plant wide /Ohmstede shop at Laporte TX: TA January 2023-Feb. 2023
- Performed visual inspections of piping systems and flange gasket seating surfaces.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
APR 2022 – APR 2022
Client: P66 Refinery Plant, West Lake, LA
P66 Refinery Plant, West Lake, LA (PSA, 10 Reformer and 2HDS units TA April 2022)
- Performed visual inspections of piping systems and flange gasket seating surfaces.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
APR 2017 – MAY 2017
Client: Tesoro Refinery Plant, North Dakota
Tesoro Refinery Plant, North Dakota T/A April 2017 - May 2017
- Performed visual inspections of piping systems and flange gasket seating surfaces.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
MAR 2017 – MAR 2017
Client: P66 Refinery Plant, Sweeny, Texas.
P66 Refinery Plant, Sweeny, Texas. T/A March 2017
- Performed visual inspections of piping systems and flange gasket seating surfaces.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
JUN 2015 – JUL 2015
Client: HollyFrontier Refinery, Salt Lake, Utah.
HollyFrontier Refinery, Salt Lake, Utah. T/A June 2015 – July 2015
- Performed visual inspections of piping systems and flange gasket seating surfaces.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
MAR 2014 – APR 2014
Client: Phillip 66 Belle Chasse, Louisiana
Phillip 66 Belle Chasse, Louisiana T/A March – April 2014
- Performed visual inspections of piping systems and flange gasket seating surfaces.
- Performed QA/QC field inspector, ensuring that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed load and pressure testing on exchangers and piping systems.
- Reviewed turnover packages from contractors to ensure compliance with customer requirements.
JUN 2023 – JUN 2023
Client: Lyondell basell Bay City, TX.
Lyondell basell Bay City, TX. June 2023
- Performed internal and external inspections of pressure vessels, exchangers, drums, heaters, and towers, adhering to the API 510 code standard.
- Witnessed all load and pressure testing on exchangers to ensure compliance with safety and operational standards.
JAN 2017 – FEB 2017
Client: Pasadena Refining System Inc. Pasadena, TX.
Pasadena Refining System Inc. Pasadena, TX. T/A January 2017 –Feb. 2017
- Performed internal and external inspections of pressure vessels, exchangers, drums, heaters, and towers, adhering to the API 510 code standard.
- Witnessed all load and pressure testing on exchangers to ensure compliance with safety and operational standards.
AUG 2022 – AUG 2022
Client: P66 Refinery Plant, Ferndale, WA
P66 Refinery Plant, Ferndale, WA (FCC, Reformer and Crude units TA Aug 2022)
- Conducted internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in accordance with API 510 code standards.
- Performed visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
MAR 2022 – MAR 2022
Client: CVR Wynnewood, OK.
CVR Wynnewood, OK. (Crude and Vac units TA March 2022)
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems, welds and flange gasket seating surfaces to ensure proper sealing and integrity.
- Performed QA field inspector, ensuring all piping fabrications, repairs, and alterations to pressure vessels met specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with safety and operational standards.
MAR 2019 – APR 2019
Client: ExxonMobil Plant, Beaumont, Texas.
ExxonMobil Plant, Beaumont, Texas. (BPEX, Project) March 2019 – Apr. 2019
Product: Vessels, piping, flanges, and control valves
- Performed QA/QC inspections on vessels, piping, flanges, and control valves to ensure compliance with specified codes and standards.
- Verified that all piping fabrications and equipment met industry requirements.
- Witnessed load and pressure testing on piping systems to confirm operational integrity.
2019 – 2019
Client: CITGO Plant. Sulphur, LA.
CITGO Plant. Sulphur, LA. (Unicracker unit TA 2019)
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in accordance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with safety and operational standards.
2017 – FEB 2019
Client: LQF and PTF FLNG Plant, Freeport, Texas.
LQF and PTF FLNG Plant, Freeport, Texas. (New Const. Project) 2017 – Feb, 2019
Product: Control valves, pressure vessels, piping systems, compressor generators
- Performed QA/QC inspections on control valves to ensure compliance with specified codes and standards.
- Verified that all piping fabrications and equipment met industry codes and specifications.
- Witnessed all load and pressure testing on piping systems to confirm operational integrity.
- Collaborated with CB&I Commissioning Group on pressure vessels, piping systems, and compressor generators during project commissioning.
JUL 2022 – JUL 2022
Client: OCI chemical Plant, Beaumont, TX.
OCI chemical Plant, Beaumont, TX. (Methanol unit TA. July, 2022)
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
MAY 2022 – MAY 2022
Client: Indorama Petrochemical. Port Arthur, TX
Indorama Petrochemical. Port Arthur, TX (T & I unit TA May 2022)
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in accordance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure proper sealing and integrity.
- Served as a QA field inspector, ensuring all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to ensure compliance with operational and safety standards.
JAN 2022 – JAN 2022
Client: Valero Refinery, Port Arthur, TX.
Valero Refinery, Port Arthur, TX. (SRU units TA Jan. 2022)
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in accordance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure proper sealing and integrity.
- Served as a QA field inspector, ensuring all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to ensure compliance with operational and safety standards.
JAN 2020 – MAR 2020
Client: Indorama Petrochemical. Port Arthur, TX
Indorama Petrochemical. Port Arthur, TX (T & I unit TA Jan.- March 2020)
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in accordance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure proper sealing and integrity.
- Served as a QA field inspector, ensuring all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to ensure compliance with operational and safety standards.
Client: Valero Refinery, Corpus Christi, TX.
Valero Refinery, Corpus Christi, TX. (SRU and AMIE units TA)
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
JUL 2021 – JUL 2021
Client: Western Midstream Gas Plant. North Reeves County, Odesa, TX.
Western Midstream Gas Plant. North Reeves County, Odesa, TX. (July 2021)
Product: Pressure vessels
- Performed internal and external inspections and maintenance on pressure vessels in compliance with API 510 code standards.
JAN 2021 – APR 2021
Client: Enterprise Gas Plant Mount Belview, Baytown. TX.; Covestro chemical Plant, Baytown, TX.
Enterprise Gas Plant Mount Belview, Baytown. TX. T/A Jan –Feb. 2021; Covestro chemical Plant, Baytown, TX. MR-1 unit T/A March – April 2021.
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
- Reviewed turnover packages from contractors and for the customer, ensuring all documentation was accurate and met project requirements.
OCT 2020 – NOV 2020
Client: Kinder Morgan Plant, South Sheridan, TX
Kinder Morgan Plant, South Sheridan, TX. Oct. – Nov. 2020
Product: Pressure vessels
- Performed internal and external inspection and maintenance on pressure vessels in compliance with API 510 code standards.
DEC 2019 – DEC 2019
Client: Kinder Morgan Plant, Montague, TX.
Kinder Morgan Plant, Montague, TX. Dec. 11, 2019
Product: Pressure vessels
- Performed internal and external inspection and maintenance on pressure vessels in compliance with API 510 code standards.
APR 2020 – APR 2020
Client: Dow Petrochem Plant, Laporte TX.
Dow Petrochem Plant, Laporte TX.
- Ensured all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes and standards.
- Witnessed all load and pressure testing on exchangers and piping systems to ensure compliance with operational and safety standards.
- Prepared and reviewed turnover packages for both the customer and contractors, ensuring all documentation met project requirements.
MAY 2019 – JUL 2019
Client: PHRC Rehabilitation Project, FCCU, Port Harcourt, Nigeria
PHRC Rehabilitation Project, FCCU (Port Harcourt, Nigeria May 2019- July 2019)
Product: FCCU structure, regenerator, cyclones, reactors, piping, pressure vessels
Standards: API 510 and API 570
Location: Port Harcourt, Nigeria
- Conducted initial walk-down on piping and equipment, reviewing the vessels' prior inspection history, repairs, and current inspection plans.
- Performed inspections on the FCCU structure, including the regenerator, cyclones, and reactors, ensuring compliance with API 510 and API 570 code standards.
- Wrote clear and precise inspection reports and recommendations in accordance with client policies and procedures.
- Conducted external piping inspections and internal inspections of pressure vessels.
- Performed Job Safety Analysis (JSA) to identify potential hazards before commencing field work activities.
AUG 2017 – SEP 2017
Client: Calcasieu Refining Co. Lake Charles, LA.
Calcasieu Refining Co. Lake Charles, LA. T/A August – Sept. 2017
- Ensured all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes and standards.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
- Prepared and reviewed turnover packages for both the customer and contractors, ensuring all documentation met project requirements.
JUL 2016 – SEP 2016
Client: Indorama Chemical Plant, Sulphur. LA.
Indorama Chemical Plant, Sulphur. LA. Revamp Project. July – Sept. 2016
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
FEB 2016 – MAR 2016
Client: Chevron Philips Refinery, Pascagoula. Mississippi.
Chevron Philips Refinery, Pascagoula. Mississippi. T/A Feb – March. 2016
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in accordance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
- Acted as a QA field inspector to ensure that all piping fabrications, repairs, and alterations to pressure vessels conformed to specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to ensure compliance with operational and safety standards.
- Prepared and reviewed turnover packages for the customer and contractors, ensuring all documentation met project requirements.
OCT 2015 – NOV 2015
Client: Coffeyville Refinery Energy, Coffeyville. Kansas.
Coffeyville Refinery Energy, Coffeyville. Kansas. T/A Oct – Nov. 2015
- Performed internal and external inspections on pressure vessels, exchangers, drums, heaters, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems and flange gasket seating surfaces to ensure integrity and proper sealing.
MAY 2015 – MAY 2015
Client: Axiall Corporation Chemical Plant, La Porte. TX.
Axiall Corporation Chemical Plant, La Porte. TX. May 2015
- Performed internal and external inspections on pressure vessels, exchangers, drums, and towers in compliance with API 510 code standards.
- Witnessed all load and pressure testing on exchangers to ensure compliance with safety and operational standards.
APR 2015 – APR 2015
Client: Dow Chemical Plant, Saint Charles, LA.
Dow Chemical Plant, (Olefin unit 1) Saint Charles, LA. April 2015
- Performed internal and external inspections on pressure vessels, exchangers, drums, and towers in compliance with API 510 code standards.
- Witnessed all load and pressure testing on exchangers to ensure compliance with safety and operational standards.
JAN 2015 – MAR 2015
Client: Valero Refinery plant, Texas City, Texas.
Valero Refinery plant, Texas City, Texas. T/A January 2015- March 2015
- Performed internal and external inspections on pressure vessels, exchangers, drums, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems to ensure integrity and compliance.
- Provided QA/QC support in the fabrication shop and as a field inspector to ensure all piping fabrications, repairs, and alterations to pressure vessels met specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
- Reviewed turnover packages from contractors to ensure all documentation met customer specifications.
JUL 2014 – JAN 2015
Client: Valero Refinery plant, Texas City, Texas.
Naphtha project (New construction MDHT unit) from July 2014 – January 2015
- Performed internal and external inspections on pressure vessels, exchangers, drums, and towers in compliance with API 510 code standards.
- Conducted visual inspections of piping systems to ensure integrity and compliance.
- Provided QA/QC support in the fabrication shop and as a field inspector to ensure all piping fabrications, repairs, and alterations to pressure vessels met specified codes.
- Witnessed all load and pressure testing on exchangers and piping systems to verify compliance with operational and safety standards.
- Reviewed turnover packages from contractors to ensure all documentation met customer specifications.
APR 2014 – MAY 2014
Client: BG Tunisia Gas Plant, Sfax in Tunisia North Africa
BG Tunisia Gas Plant, Sfax in Tunisia North Africa (April 28 – May 30, 2014)
Location: Sfax, Tunisia North Africa
- Performed internal and external inspections on pressure vessels, exchangers, drums, and towers in compliance with API 510 code standards.
Skills
- Mechanical Integrity
- API 510 Inspection
- QA/QC Inspection
- Pressure Vessel Inspection
- Piping Inspection
- Welding and Visual Inspection
- NDT
- Inspection Reporting
- Turnover Package Review
- Job Safety Analysis
Commodities
- Pressure Vessels
- Heat Exchangers
- Drums
- Heaters
- Towers
- Piping Systems
- Welds
- Flanges
- Gasket Seating Surfaces
- Control Valves
- Pipe Rack Structures
- Reactors
- Regenerator
- Cyclones
- Compressors
- Generators